62013.jpg

 

Technical Data

Type

BT PCM TNS 275 RM

BT PCM TNS 320 RM

BT PCM TNS 385 RM

According to IEC 61643-11/EN 61643-11

Class II / Type 2

Class II / Type 2

Class II / Type 2

Art.-No.

810834

810887

810835

Nominal a.c. voltage [UN]

230V/400V

230V/400V

230V/400V

Rated voltage (max. continuous a.c. voltage) [Uc]

275V

320V

385V

TOV withstand 5sec[UT]

336.6V

335V

335V

TOV 120 min(safe fail)[UT]

440V

440V

440V

Frequency[Hz]

50/60 Hz

50/60 Hz

50/60 Hz

Nominal discharge current (8/20μs) [In]

20kA

20kA

20kA

Max. discharge current (8/20μs) [Imax]

40kA

40kA

40kA

Voltage protection level at In [Up]

≤1.3kV

≤1.5kV

≤1.8kV

Voltage protection level at 5kA [Up]

≤1.0kV

≤1.2kV

≤1.35kV

Response time [tA]

≤ 25ns

Max. back up fuse [F]

125A gL/gG

Operating temperature range [Tu]

-40°C...+80°C

Cross-sectional area

1.5mm2(16AWG) ~ 25mm2(4AWG) solid / 35mm2(2AWG) flexible

Mounting on

35mm DIN rail,EN 60715

Operating state / Failure indication 

Green:ok / Red: faulty 

Dimension 

4 mods (72mm wide) 

Enclosure material

Purple & light gray (base) thermoplastic, UL94-V0

Test standards

 IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Certification

KEMA-KEUR; CB; CE; RoHS

Number of remote terminals

1(or Optional) 

Type of remote signaling contact

Switching contact

Switching capacity(UN/IN)

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A

Cross-sectional area for remote signaling contact

Max. 1.5mm2 (16AWG)solid/flexible

.png

 Application Scenarios

Pluggable SPD Class II for three-phase TN-S (“4+0 circuit) power supply systems.

Hightlight Features

1. Pluggable module, easy for installation and maintenance.

2. High discharge capacity, quick response.

3. Double thermal disconnector devices, providing more reliable protection.

4. Green window will change when fault and also provide remote alarm control at the same time.

5. Surge protection device has passed KEMA-KEUR certification.

6. Suitable for use in three phase: 220V/380V(50/60 Hz), 230V/400V(50/60 Hz) and 240V/415V(50/60 Hz) AC systems.

7. Suitable for TN-S installations.

8. Crafted from selected flame-retardant enclosure, it effectively combats the spread of fire, buying critical time to protect life and property.

9. Powered by advanced European technology, it provides comprehensive and reliable protection for electrical equipment.

 9.jpg10.jpg11.jpg12.jpg

 

Summary

Designed for installation in LPZ 0B-1 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional.

Application:Pluggable SPD Class II for three-phase TN-S (“4+0 circuit) power supply systems.

Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.

1.jpg

FAQ

 

 

 

 

 

 

GET IN TOUCH