All Categories
AC SPD Class II

AC SPD Class II

Telebahn AC SPD 4P 120V 150V 10kA-20kA 20kA -40kA 30kA-60kA T2 Surge Protector Supresor De Picos Suppressor De Sobretensiones

Inquiry
  • Overview
  • Inquiry
  • Related Products
Product Description

 

12.jpgCircuit.jpgDiemsion.jpgMounting.jpg

 

Technical Data

Type

BT PCM20 150 RM/4P

BT PCM TNS 150 RM

BT PCM60 150 RM/4P

BT PCM TNS 385 RM

Art.-No.

810860

810833

810840

810835

Nominal a.c. voltage [UN]

120V/240V

120V/240V

120V/240V

230V/400V

Rated voltage (max. continuous a.c. voltage) [Uc]

150V

150V

150V

385V

Frequency[Hz]

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

Nominal discharge current (8/20μs) [In]

10kA

20kA

30kA

20kA

Max. discharge current (8/20μs) [Imax]

20kA

40kA

60kA

40kA

Voltage protection level[Up]

≤0.7kV

≤0.9kV

≤1.2kV

≤1.8kV

Certification

CE;RoHS 

CE;RoHS;KEMA;CB 

CE; RoHS 

 CE;RoHS;KEMA;CB 

Response time [tA]

≤ 25ns

Max. back up fuse [F]

125A gL/gG

Operating temperature range [Tu]

-40°C...+80°C

Cross-sectional area

1.5mm2(16AWG) ~ 25mm2(4AWG) solid / 35mm2(2AWG) flexible

Mounting on

35mm DIN rail,EN 60715

Operating state / Failure indication 

Green:ok / Red: faulty 

Dimension 

4 mods (72mm wide) 

Enclosure material

Purple & light gray (base) thermoplastic, UL94-V0

Compliance

IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Number of remote terminals

1(or Optional) 

Type of remote signaling contact

Switching contact

Switching capacity(UN/IN)

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A

Cross-sectional area for remote signaling contact

Max. 1.5mm2 (16AWG)solid/flexible

 

Application Scenarios

Pluggable SPD Class II for three-phase TN-S (“4+0 circuit) power supply systems.

Highlight Features

1. Pluggable module, easy for installation and maintenance.

2. High discharge capacity, quick response.

3. Double thermal disconnector devices, providing more reliable protection.

4. Green window will change when fault and also provide remote alarm control at the same time.

5. Suitable for use in three phase AC systems.

6. Suitable for TN-S installations.

7. Crafted from selected flame-retardant enclosure, it effectively combats the spread of fire, buying critical time to protect life and property.

8. Powered by advanced European technology, it provides comprehensive and reliable protection for electrical equipment.

 

Summary

Designed for installation in LPZ 1-2 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional.

Application:Pluggable SPD Class II for three-phase TN-S (“4+0 circuit) power supply systems.

Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.

.jpg

 

FAQ

 

 

 

 

 

 

GET IN TOUCH