All Categories
AC SPD Class I

AC SPD Class I

Telebahn 120V/240V AC 4P 20kA 50kA 8kA 200kA SPD Surge Protectors Arrester for 3 Phase High Leg Delta 4W+G electrical systems

Inquiry
  • Overview
  • Inquiry
  • Related Products
Product Description

  Technical data

Type

BT PUM 4WD 240 RM/4P

BT PUM 4WD 480 RM/4P

UL1449 - SPD

Open-Type 1

System type

3 Phase High Leg / 4W+G

Nominal system AC voltage (50/60Hz) [UN]

120V/240V Delta

240V/480V Delta

Max. continuous operating voltage AC [MCOV] 

(L-N)/(L-G)/(N-G)/(L-L)/(H-N)/(H-G)/(L-H)

230V/410V/180V/460V/275V/455V/505V

385V /565V/180V/ 770V/510V/690V/895V

Nominal discharge current (8/20µs) [In] 

20kA 

20kA 

Max. discharge current (8/20µs) [Imax] 

50kA 

50kA 

Lighting impulse current (10/350µs)

8kA

--

Voltage protection rating  [VPR] 

(L-N)/(L-G)/(N-G)/(L-L)/(H-N)/(H-G)/(L-H)

0.7kVpk /1.2kVpk/0.6kVpk/1.5kVpk/0.8kVpk/1.5kVpk /1.5kVpk

1.2kVpk/1.8kVpk/0.6kVpk/2.5kVpk/1.5kVpk/2.0kVpk/2.5kVpk

Short circuit current rating [SCCR] 

200kA

200kA

 Max. backup fuse [F]

125A gL/gG

Operating temperature range [Tu]Operating state / Failure indication 

-35°C...+85°CGreen / Red 

Cross-sectional area

2.5mm2 ~ 25mm2 solid/flexible

Mounting on / Number of remote terminals 

35mm DIN rail / 1

Enclosure material

Red module / light gray base, thermoplastic, UL 94-V0

Dimension Degree of Protection 

4 mods (72mm wide) / IP 20

Test standards

IEC 61643-11; UL 1449-4th; GB/T 18802.11

Certification

CE (LVD, EMC); RoHS

Type of remote signaling contact Orientation for normal installation

Switching contact In door

Switching capacity a.c.

250V/0.5A

Switching capacity d.c.

250V/0.1A, 125V/0.2A, 75V/0.5A

Cross-sectional area for remote signaling contact

Max. 1.5mm2 solid/flexible

Ordering information

Type

BT PUM 4WD 240 RM/4P

BT PUM 4WD 480 RM/4P

Art.-No.

815 083

815 088

Packing unit

1pc(s)

1pc(s)

 

Image_BT PUM 4WD 240 RM_4P.jpgDimension.jpgBT PUM 4WD 240 480 RM 4P.pngSystem.jpg

Hightlight Features

•  Combined module SPD for 3 Phase High Leg Delta electrical systems(4W+G circuit)  .  

•  Max. Discharge current (Imax) up to 50kA 8/20μs.

•  Short-circuit current rating (SCCR) 200kA.

•  Double thermal disconnector device, providing more reliable protection.

•  Green window will change when fault and also provide remote alarm control at the same time.

Summary

BT PUM 4WD 240 RM/4P(815083) Surge protector Device is mainly used in the main distribution system, provide the best protection as they designed to protecting low voltage equipment against indirect surges with ensuring a low protection level (VPR).

    Application in AC voltage system of 3 Phase High Leg Delta electrical systems(4W+G circuit), for example, computer, communication, or control equipment. Designed according to IEC 61643-11 and UL 1449-4th type 4-1 combined SPD Modules.