Factory Telebahn 240V/480V 385V 770V AC 20kA 50kA 8kA 200kA Split Phase 3W+G Surge Protectors Suppressor Lightning Arrester SPD
- Overview
- Inquiry
- Related Products
Technical data
|
Type |
BT PUM SP 240 RM/2P |
BT PUM SP 480 RM/2P |
|
UL1449 - SPD |
Open-Type 1 |
|
|
System type |
Split Phase / 3W+G |
|
|
Nominal system voltage (50/60Hz) [VAC] |
120V/240V or 127V/254V |
240V/480V |
|
Max. continuous operating voltage AC [MCOV] [L-G] / [L-L] |
230V / 460V |
385V / 770V |
|
Nominal discharge current (8/20µs) [In] |
20kA |
20kA |
|
Max. discharge current (8/20µs) [Imax] |
50kA |
50kA |
|
Lighting impulse current (10/350µs) |
8kA |
8kA |
|
Voltage protection rating [VPR] [L-G] / [L-L] |
700Vpk / 1500Vpk |
1200Vpk / 2500Vpk |
|
Short circuit current rating [SCCR] |
200kA |
200kA |
|
Max. backup fuse [F] |
125A gL/gG |
|
|
Operating temperature range [Tu], Operating state / Failure indication |
-35°C...+85°C, Green / Red |
|
|
Cross-sectional area |
2.5mm2 ~ 25mm2 solid/flexible |
|
|
Mounting on / Number of remote terminals |
35mm DIN rail / 1 |
|
|
Enclosure material |
Red module / light gray base, thermoplastic, UL 94-V0 |
|
|
Dimension / Degree of Protection |
2 mod (36mm wide) / IP 20 |
|
|
Test standards |
IEC 61643-11; UL 1449-4th; GB/T 18802.11 |
|
|
Certification |
CE (LVD, EMC); RoHS |
|
|
Type of remote signaling contact / Orientation for normal installation |
Switching contact / In door |
|
|
Switching capacity a.c. |
250V/0.5A |
|
|
Switching capacity d.c. |
250V/0.1A, 125V/0.2A, 75V/0.5A |
|
|
Cross-sectional area for remote signaling contact |
Max. 1.5mm2 solid/flexible |
|
|
Ordering information |
||
|
Type |
BT PUM SP 240 RM/2P |
BT PUM SP 480 RM/2P |
|
Art.-No. |
815 042 |
815 045 |
|
Packing unit |
1pc(s) |
1pc(s) |




Hightlight Features
• Combined module SPD for Split Phase electrical systems with N wire protected.
• Max. Discharge current (Imax) up to 50kA 8/20μs.
• Short-circuit current rating (SCCR) 200kA.
• Double thermal disconnector device, providing more reliable protection.
• Green window will change when fault and also provide remote alarm control at the same time.
Summary
BT PUM SP 240 RM/2P(815042) Surge protector Device is mainly used in the main distribution system, provide the best protection as they designed to protecting low voltage equipment against indirect surges with ensuring a low protection level (VPR).
Application in AC voltage system of Split Phase electrical systems with N wire protected, for example, computer, communication, or control equipment. Designed according to IEC 61643-11 and UL 1449-4th type 4-1 combined SPD Modules.








EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
HI
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
UK
VI
SQ
ET
GL
HU
MT
TH
TR