All Categories
AC SPD Class II

AC SPD Class II

BT PCM80 275 RM/4P Surge Protective Device

Inquiry
  • Overview
  • Inquiry
  • Related Products

4.jpg

Product Description

Surge Protective Device Data

Type

 

BT PCM80 275 RM/4P

 

According to IEC 61643-11/EN 61643-11

Class II (class 2/C) / Type 2

System mode

3 Phase TNS System (“ 4+0 " circuit)

Nominal a.c. voltage  [UN](50/60Hz) 

230V/400V

Rated voltage (max. continuous voltage) [Uc]( 50/60Hz )

275V  

Nominal discharge current (8/20μs) [In] 

40kA  

Max. discharge current (8/20μs) [Imax] 

80kA  

Modules

4P

Voltage protection level at In [Up] 

≤ 1.5kV

Voltage protection level at 5kA [Up] 

≤ 1.2kV

Response time [tA] 

≤ 25ns

Max. back up fuse [F]

125A gL/gG

Operating temperature range [Tu] 

-40°C...+80°C 

Cross-sectional area 

1.5mm2 ~ 25mm2 solid / 35mm2 flexible

Mounting on

35mm DIN rail, According to EN 60715

Number of remote terminals

1 or Selectable 

Degree of Protection 

IP 20

Failure indication 

Red

Dimension

4 mods (72mm)

Enclosure material

 Light gray thermoplastic, UL94-V0

Type of remote signaling contact

Switching contact

Switching capacity a.c.

250V/0.5A

Switching capacity d.c.

250V/0.1A, 125V/0.2A, 75V/0.5A

Place of installation

Indoor

Cross-sectional area for remote signaling contact

Max. 1.5mm2 solid/flexible

Test standards

IEC 61643-11; EN 61643-11; GB/T 18802.11

Certification

CE; RoHS

Ordering information

Type

BT PCM80 275 RM/4P

Art.-No.

810761

Packing unit

1pc(s)

 

14.jpg15.jpg20.jpg21.jpg 

Surge Protective Device Features

•  Pluggable module, easy for installation and maintenance.

•  Consist of double varistors and thermal disconnection devices.

•  High discharge capacity, quick response.

•  Double thermal disconnector devices, providing more reliable protection.

•  Window will change to red when fault occurs and also provide remote alarm control at the same.

Surge Protective Device Surmmary

BT PCM80 275 RM/4P surge protective device is for installation at LPZ 0B-1 or higher, protecting low voltage equipment from surge damage. Applied in modular SPD Class II (Class C) for TN-S (“4+0” circuit ) power supply system. Designed according to IEC 61643-11; EN 61643-11; GB/T 18802.11.

1BT PCM80 275 RM/4P Surge Protective Device detailsBT PCM80 275 RM/4P Surge Protective Device supplierBT PCM80 275 RM/4P Surge Protective Device supplierBT PCM80 275 RM/4P Surge Protective Device manufactureBT PCM80 275 RM/4P Surge Protective Device manufactureFAQBT PCM80 275 RM/4P Surge Protective Device factory 

 

 

GET IN TOUCH