Telebahn Solar Photovoltaic System Surge Protector Device CE RoHS DPS T2 20kA 40KA 2P PV DC 150V 600V 1000V SPD
- Overview
- Inquiry
- Related Products
Product Description


Technical data
Type
BT PVM 1000 RM/2P
Nominal d.c. (PV) voltage [UN]
1000V
Short-circuit current rating [ ISCPV ]
1kA
Max continuous d.c. voltage [Uc]
1060V
Total discharge current (8/20) [ In total]
40kA
Nominal discharge current (8/20) [In]
20kA
Max. discharge current (8/20) [Imax]
40kA
Voltage protection level at In [Up]
≤ 4kV
Voltage protection level at 5kA [Up]
≤ 3.5kV
Response time [tA]
≤ 25ns
Operating temperature range [Tu]
-40°C...+80°C
Cross-sectional area
1.5mm2 ~ 25mm2 solid / flexible
Mounting on
35mm DIN rail
Enclosure material
Purple (module) / Light grey (base) thermoplastic, UL94-V0
Dimension
2 mods (36mm)
Test standards
IEC 61643-11; EN 61643-11; GB 18802.11
Certification
CE (LVD, EMC); RoHS
Type of remote signalling contact
Switching contact
Switching capacity a.c.
AC:250V/0.5A
Switching capacity d.c.
DC:250V/0.1A;150V/0.2A;750V/0.5A
Cross-sectional area for remote signalling contact
Max. 1.5mm2 solid / flexible
Ordering information
Type
BT PVM 1000 RM/2P
Art.-No.
800 501
Packing unit
1pc(s)
Summary
BT PVM 150/600/1000 RM/2P surge protection according to EN 50539-11 is for max. dc voltage 150V/600V/1000V system and applied in photovoltaic system, Prevent surge and direct lightning, Designed according to IEC 61643-11/EN61643-11.
Hightlight Features
1. Combined class II DC surge protector for Photovoltaic(PV) System.
2. Pluggable module, easy for installation and maintenance.
3. Approved falult-resistant Y-circuit, consist of two varistors and thermal disconnection devices.
4. High discharge capacity, quick response.
5. Double thermal disconnection device, providing more reliable protection.
6. Integrated DC-fuse allows safe replacement of protection modules without arc formation.
7. Green window will change when fault and also provide remote alarm control at the same time.











Technical data
|
Type |
BT PVM 1000 RM/2P |
|
Nominal d.c. (PV) voltage [UN] |
1000V |
|
Short-circuit current rating [ ISCPV ] |
1kA |
|
Max continuous d.c. voltage [Uc] |
1060V |
|
Total discharge current (8/20) [ In total] |
40kA |
|
Nominal discharge current (8/20) [In] |
20kA |
|
Max. discharge current (8/20) [Imax] |
40kA |
|
Voltage protection level at In [Up] |
≤ 4kV |
|
Voltage protection level at 5kA [Up] |
≤ 3.5kV |
|
Response time [tA] |
≤ 25ns |
|
Operating temperature range [Tu] |
-40°C...+80°C |
|
Cross-sectional area |
1.5mm2 ~ 25mm2 solid / flexible |
|
Mounting on |
35mm DIN rail |
|
Enclosure material |
Purple (module) / Light grey (base) thermoplastic, UL94-V0 |
|
Dimension |
2 mods (36mm) |
|
Test standards |
IEC 61643-11; EN 61643-11; GB 18802.11 |
|
Certification |
CE (LVD, EMC); RoHS |
|
Type of remote signalling contact |
Switching contact |
|
Switching capacity a.c. |
AC:250V/0.5A |
|
Switching capacity d.c. |
DC:250V/0.1A;150V/0.2A;750V/0.5A |
|
Cross-sectional area for remote signalling contact |
Max. 1.5mm2 solid / flexible |
|
Ordering information |
|
|
Type |
BT PVM 1000 RM/2P |
|
Art.-No. |
800 501 |
|
Packing unit |
1pc(s) |
Summary
BT PVM 150/600/1000 RM/2P surge protection according to EN 50539-11 is for max. dc voltage 150V/600V/1000V system and applied in photovoltaic system, Prevent surge and direct lightning, Designed according to IEC 61643-11/EN61643-11.
Hightlight Features
1. Combined class II DC surge protector for Photovoltaic(PV) System.
2. Pluggable module, easy for installation and maintenance.
3. Approved falult-resistant Y-circuit, consist of two varistors and thermal disconnection devices.
4. High discharge capacity, quick response.
5. Double thermal disconnection device, providing more reliable protection.
6. Integrated DC-fuse allows safe replacement of protection modules without arc formation.
7. Green window will change when fault and also provide remote alarm control at the same time.









EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
HI
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
UK
VI
SQ
ET
GL
HU
MT
TH
TR