All Categories
Photovoltaic(PV)System & DC SPD

Photovoltaic(PV)System & DC SPD

60V DC SPD 2P 25kA T1 Low Voltage Surge Protection Device Surge Protector Parafoudre for DC Power Supply System

Inquiry
  • Overview
  • Inquiry
  • Related Products
Product Description

 .png

 

 

Technical Data

Type

BT P BDCM25 48 RM/2P

BT P BDCM25 200 RM/2P

BT P BDCM25 220 RM/2P

According to IEC 61643-11/EN 61643-11

Class I / Type 1

Class I / Type 1

Class I / Type 1

Art.-No.

802044

802045

802046

Nominal d.c. voltage [UN]

48V

200V

220V

Rated voltage (max. continuous d.c. voltage) [Uc]

60V

220V

242V

Lightning impulse current (10/350μs) [Iimp](DC+ →PE/DC- → PE )

25kA

25kA

25kA

Specific energy[W/R] 

156.25kJ/ohms

156.25kJ/ohms

156.25kJ/ohms

Nominal discharge current (8/20µs) [In](DC+ →PE/DC- → PE ) 

25kA

25kA

25kA

Voltage protection level at In [Up]

≤1.5kV

≤2.5kV

≤2.5kV

Follow current extinguishing capability at DC[If]

2kA

Response time [tA](DC+ →PE/DC- → PE )

≤ 100ns

Max. back up fuse [F]

200A gL/gG

Operating temperature range [Tu]

-40°C...+80°C

Cross-sectional area

35mmsolid / 50mm2 flexible

Mounting on

35mm DIN rail,EN 60715

Operating state / Failure indication 

Green:ok / Red: faulty 

Dimension 

4 mods (72mm wide) 

Enclosure material

Purple & light gray (base) thermoplastic, UL94-V0

Test standards

 IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Certification

CE; RoHS

Number of remote terminals

1(or Optional) 

Type of remote signaling contact

Switching contact

Switching capacity(UN/IN)

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A

Cross-sectional area for remote signaling contact

Max. 1.5mm2 solid/flexible

 

(For more detailed information, please feel free to contact us. We will be happy to send you the relevant documentation. We Support Both OEM and ODM, with No Extra Cost for These Services. )

.png 

 Application Scenarios

Pluggable SPD Class I for DC power supply systems (“2+0 circuit).

Hightlight Features

1. Pluggable module, 10/350us and 8/20us sparkgap (GDT).

2. Lightning discharge current up to 25kA for use in dccircuits applications.

3. High discharge capacity, quick response.

4. Mode of protection: DC+ →PE/DC- → PE .

5. Double thermal disconnector device, providing more reliable protection.

6. Green window will change when fault and also provide remote alarm control at the same time.

7. Crafted from selected flame-retardant enclosure and Utilizing advanced European technology to ensure complete and reliable safeguarding of electrical equipment.

 

 

Summary

Designed for installation in LPZ 0A-1 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional.

Application:Pluggable SPD Class I for DC power supply systems (“2+0 circuit).

Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.