All Categories
SPD Box

SPD Box

Single Phase AC SPD 240V T1+T2+T3 Full Surge Protection Box

Inquiry
  • Overview
  • Inquiry
  • Related Products

 

3

1

Technical Data

Type

BT 3L BM 240 RM

Art.-No.

840242

According to EN 61643-11, IEC 61643-11

Type 1 + Type 2 + Type 3 / Class I +Class II + Class III

Nominal a.c. voltage [UN] (L-N)

240V

Rated voltage (max. continuous voltage) [Uc](L-N)

280V

Transient overvoltage TOV[UT

350V

Short-circuit withstand capability

25kA/50Hz

Operating voltage

200-280V

Frequency range[F]

47-63Hz

Leakage current (to the ground)

<250μA

Indicator circuit current

<10mA

Lightning impulse current (10/350μs[Iimp]

6.25kA

Max. Lightning impulse current (10/350μs) [Iimp](L+N-PE)

12.5kA

Nominal discharge current (8/20μs) [In]

20kA

Max. discharge current (8/20μs) [Imax]

40kA

Voltage protection level at In[Up]

≤ 1.2kV

Voltage protection 1.2/50 6kV@3kA[Up]

≤ 0.6kV

Max. back up fuse [F]

125A gL/gG

perating temperature range [Tu]/Enclosure material

-40°C...+80°C/Black metal housing

Connection type

Screw terminals 

Wiring conductor cross section

10mm2 ~ 25mmsolid /35mm2 flexible

Switching capacity a.c

AC: 250V/0.5A

Compliance

IEC 61643-11:2011 ; EN 61643-11:2012; GB /T 18802.11-2020

Certification

CE (LVD, EMC); RoHS;REACH

Type of remote signalling contact

Switching contact 

Switching capacity d.c

DC: 250V/0.1A; 150V/0.2A; 750V/0.5A

Cross-sectional area for remote signalling contact

Max 1.5mm2 (solid/flexible)

.png

Hightlight Features

1. All wires (phase line to neutral line, phase line to ground, neutral line to ground full protection mode) voltageprotection level is very low.
2. Full protection design, able to handle part of lightning current, protection equipment can continue normal operation.

3. Visual protection status indication, with pre-failure indication and failure indication function.

4. With remote alerting function, remote waming signal can be connected to the remote monitoring management
system platform buzzer or LED.
5. Visual warning indication of neutral/ground line fault due to faulty wiring.
6. Solid housing, base can be used as ultra-low inductance grounding metal panel.

7. Suitable for use in single phase:220V-240V(50/60 Hz) AC systems.

Summary

BT 3L BM 240 RM(820301)is installed in the LPZ 0B -1, interface and is mainly used in the main distribution system toprotect the connected electronic devices from the transient over voltage on the power supply. For example.computer,communication or control equipment. Applied in single phase type 1 +type 2 +type 3 for various power supply system.

1FAQ

 

 

GET IN TOUCH