All Categories
SPD Box

SPD Box

AC SPD 240V T2+T3 Surge Protective Device Surge Protector Box for Single Phase

Inquiry
  • Overview
  • Inquiry
  • Related Products
Product Description

 2.jpg20.jpg

 

 

Technical Data

Type

BT 3L 240 RM

BT 3L BM 240 RM

Art.-No.

840240

840242

According to IEC 61643-11/EN 61643-11

Class II + Class III  / Type 2 + Type 3

Class I + Class II + Class III  / Type 1 + Type 2 + Type 3

Nominal a.c. voltage [UN](L-N)

240V

240V

Rated voltage (max. continuous a.c. voltage) [Uc](L-N)

280V

280V

Transient overvoltage TOV[UT]

350V

350V

Short-circuit withstand capability

25kA/50Hz

25kA/50Hz

Operating voltage

346-484V

346-484V

Frequency range[F]

47-63Hz

47-63Hz

Leakage current (to the ground)

<250μA

<250μA

Indicator circuit current

<10mA

<10mA

Lightning impulse current (10/350μs) [Iimp]

-

6.25kA

Total Lightning impulse current (10/350μs) [Iimp]

-

12.5kA

Nominal discharge current (8/20μs) [In](per mode)

20kA

20kA

Residual voltage [Up]

≤1.2kV

≤1.2kV

Max. discharge current (8/20μs) [Imax](per mode)

40kA

40kA

Voltage protection level 1.2/50 6kV@3kA[Up]

≤0.6kV

≤0.6kV

Max. back up fuse [F]

125A gL/gG

Operating temperature range [Tu]

-40°C...+80°C

Operating state / Failure indication 

Green:ok / Red: faulty 

Dimension 

195x130x83(mm)

Enclosure material

Black metal(Iron) housing

Connection type 

Screw terminals 

Degree of Protection

IP 20

Wiring conductor cross section

10mm2 ~ 16mm2 

Test standards

 IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Certification

CE; RoHS

 

(For more detailed information or other voltages, please feel free to contact us. We will be happy to send you the relevant documentation. We Support Both OEM and ODM, with No Extra Cost for These Services.)  

 Application Scenarios

BT 3L 240 RM: T2+T3 3 Phase AC Full Protection Sub-Distribution Boards.

 BT 3L BM 240 RM: T1+T2+T3 3 Phase AC Full Protection Main Distribution Boards.

Hightlight Features

1. All wires (phase line to neutral line, phase line to ground, neutral line to ground full protection mode) voltage protection level is very low.
2. Full protection design, able to handle part of lightning current, protection equipment can continue normal operation.

3. Visual protection status indication, with pre-failure indication and failure indication function.

4. With remote alerting function, remote warning signal can be connected to the remote monitoring management system platform buzzer or LED.
5. Visual warning indication of neutral/ground line fault due to faulty wiring.

6. Mode of protection:L,N, G.
7. Solid housing, base can be used as ultra-low inductance grounding metal panel.

8. Suitable for use in three phase: 220V/230V/240V AC 50/60 Hz systems compatible.

 

 Mounting_BT 3L 240 RM.jpg12.jpg

 

Summary

BT 3L 240 RM(840240) power surge protector is installed in the LPZ0B -1, interface and is mainly used in the main distribution system toprotect the connected electronic devices from the transient over voltage on the power supply. For example.computer,communication or control equipment. Applied in single phase type 2 +type 3 for various power supply system. 

2.jpg

FAQ

 

 

 

 

 

 

GET IN TOUCH