Type |
BT P BDCM25 48 RM/2P |
BT P BDCM25 200 RM/2P |
BT P BDCM25 220 RM/2P |
|
According to IEC 61643-11/EN 61643-11 |
Class I / Type 1 |
Class I / Type 1 |
Class I / Type 1 |
|
Art.-No. |
802044 |
802045 |
802046 |
|
Nominal d.c. voltage [UN] |
48V |
200V |
220V |
|
Rated voltage (max. continuous d.c. voltage) [Uc] |
60V |
220V |
242V |
|
Lightning impulse current (10/350μs) [Iimp](DC+ →PE/DC- → PE ) |
25kA |
25kA |
25kA |
|
Specific energy[W/R] |
156.25kJ/ohms |
156.25kJ/ohms |
156.25kJ/ohms |
|
Nominal discharge current (8/20µs) [In](DC+ →PE/DC- → PE ) |
25kA |
25kA |
25kA |
|
Voltage protection level at In [Up] |
≤1.5kV |
≤2.5kV |
≤2.5kV |
|
Follow current extinguishing capability at DC[If] |
2kA |
||
|
Response time [tA](DC+ →PE/DC- → PE ) |
≤ 100ns |
||
|
Max. back up fuse [F] |
200A gL/gG |
||
|
Operating temperature range [Tu] |
-40°C...+80°C |
||
|
Cross-sectional area |
35mm2 solid / 50mm2 flexible |
||
|
Mounting on |
35mm DIN rail,EN 60715 |
||
|
Operating state / Failure indication |
Green:ok / Red: faulty |
||
|
Dimension |
4 mods (72mm wide) |
||
|
Enclosure material |
Purple & light gray (base) thermoplastic, UL94-V0 |
||
|
Test standards |
IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020 |
||
|
Certification |
CE; RoHS |
||
|
Number of remote terminals |
1(or Optional) |
||
|
Type of remote signaling contact |
Switching contact |
||
|
Switching capacity(UN/IN) |
AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A |
||
|
Cross-sectional area for remote signaling contact |
Max. 1.5mm2 solid/flexible |
||
(For more detailed information, please feel free to contact us. We will be happy to send you the relevant documentation. We Support Both OEM and ODM, with No Extra Cost for These Services. )
Application Scenarios
Pluggable SPD Class I for DC power supply systems (“2+0” circuit).
Hightlight Features
1. Pluggable module, 10/350us and 8/20us sparkgap (GDT).
2. Lightning discharge current up to 25kA for use in dccircuits applications.
3. High discharge capacity, quick response.
4. Mode of protection: DC+ →PE/DC- → PE .
5. Double thermal disconnector device, providing more reliable protection.
6. Green window will change when fault and also provide remote alarm control at the same time.
7. Crafted from selected flame-retardant enclosure and Utilizing advanced European technology to ensure complete and reliable safeguarding of electrical equipment.
Summary
Designed for installation in LPZ 0A-1 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional.
Application:Pluggable SPD Class I for DC power supply systems (“2+0” circuit).
Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.







EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
HI
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
UK
VI
SQ
ET
GL
HU
MT
TH
TR