 3

1.png

Technical Data

Type

BT P BDCM25 48 RM

BT P BDCM25 200 RM BT P BDCM25 220 RM

According to IEC 61643-11 / EN 61643-11

Class I + Class II / Type 1 + Type 2 

Class I + Class II / Type 1 + Type 2  Class I + Class II / Type 1 + Type 2 

Art.-No.

802048

802049 802050

Nominal d.c. voltage  [UN]

48V 200V 220V

Rated voltage (max. continuous d.c voltage) [Uc]

60V

220V

242V

Lightning impulse current (10/350μs) [Iimp]

25kA

25kA

25kA

Specific energy[W/R] 

156.25kJ/ohms

156.25kJ/ohms

156.25kJ/ohms

Nominal discharge current (8/20μs) [In

25kA

25kA

25kA 

Voltage protection level at In [Up]

≤ 1.5kV

≤ 2.5kV 

≤ 2.5kV 

Response time [tA]

 ≤ 100ns

Max. back up fuse (L) [F]

200A gL/gG

Max. back up fuse [F]

125A gL/gG

Operating temperature range [Tu]

40°C…+80°C(parallel wiring) / -40°C…+60°C(series wiring)

Relative humidity

≤ 95% (25°C)

Degree of protection

IP20 

Cross-sectional area

 35mm2 solid / 50mm2 flexible

Mounting on

35mm DIN rail, EN 60715 

Enclosure material

Purple & light grey (base) thermoplastic, UL94-V0

Number of Remote terminal

1 (or Optional)

Dimension 

2 mod (36 mm wide) 

Compliance

IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Certification

KEMA-KEUR, CE(LVD,EMC), CB, RoHS;REACH;ISO 9001:2015

Type of remote signalling contact

Switching contact

Switching capacity

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;750V/0.5A

Cross-sectional area for remote signalling contact

Max. 16AWG/1.5mm2 solid/flexible

.png

Hightlight Features

1. Pluggable module, 10/350us and 8/20us sparkgap (GDT).

2. Lightning discharge current up to 25kA for use in dccircuits applications.

3. High discharge capacity, quick response.

4. Double thermal disconnector device, providing more reliable protection.

5. Green window will change when fault and also provide remote alarm control at the same time.

 

Application environment

Temperature:-40°C~+80°C

Relative humidity:≤ 95%(25°C)

Summary

BT P BDCM25 48 RM(802048) is for installation at LPZ 0A -1 or higher,protecting low voltage equipment against lightning and surge damages and remote terminal is optional. Applied in SPD Type l+ll (Class B+C) for various DC power supply system.Designed according to IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020.

Other

As China's first batch surge protection device manufacturer, we are committed to producing high-quality surge protection device while providing customized solutions for global industry leaders for over 30 years. Welcome OEM and ODM!

1FAQ

 

 

 