Technical data

Type

BT P BCM 275/1+N

BT P BCM 275 RM/1+N

Art.-No. 

801106

According to IEC 61643-11/EN 61643-11

 Class I + Class II  / Type 1+ Type 2

Type of remote signaling contact

-

Switching contact

Switching capacity(UN/IN)

-

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A

Cross-sectional area for remote signaling contact

-

Max. 1.5mm2 (16AWG)solid/flexible

Number of remote terminals

0

1

AC Nominal voltage  [UN]

230V

Rated voltage (max. continuous voltage) [Uc]

275V(L-N)   255V(N-PE)

Power system frequency[Hz]

50/60 Hz

Total lightning impulse current (10/350μs) [Iimp]

16kA(L+N-PE)

Lightning impulse current (10/350μs) [Iimp]

8kA(L-N)   20kA(N-PE)

Nominal discharge current (8/20μs) [In]

25kA(L-N)   40kA(N-PE)

Max. discharge current (8/20μs) [Imax]

50kA(L-N)   65kA(N-PE)

Voltage protection level at In [Up]

 ≤1.5kV(L-N)   ≤1.5kV(N-PE)

Response time [tA]

≤ 25ns(L-N)  ≤ 100ns(N-PE)

Max. back up fuse [F]

125A gL/gG

Cross-sectional area 

1.5mm2(16AWG) ~ 25mm2(4AWG) solid / 35mm2(2AWG) flexible

Operating state / Failure indication 

Green:ok / Red: faulty 

Operating temperature range [Tu]

-40°C...+80°C

Mounting on 

35mm DIN rail, EN 60715 

Enclosure material

L-N(red) +N-PE(black)module & light gray (base) thermoplastic, UL94-V0

Dimension 

2 mods (36mm wide) 

Test standards

 IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Certification

CE; RoHS

14.jpg16.jpg18.jpg

Hightlight Features

1. Pluggable module, easy for installation and maintenance.

2. High discharge capacity, quick response.

3. Double thermal disconnector devices, providing more reliable protection.

4. Max. lightning discharge current up to 8kA 10/350 (L-N).

5. Green window will change when fault and also provide remote alarm control at the same time.

6. Power system frequency:50/60 Hz.

7. Suitable for use in single phase 220V-240V AC systems.

8. Suitable for TT/ TN installations.

11.jpg

17.jpg

 

Summary

BT P BCM 275 RM/1+N(801106) Designed for installation in LPZ 0A-2 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional. Application: Pluggable SPD Class I + Class II for single-phase TT/TN ("1+1" circuit) power supply systems. Compliance Standards: IEC 61643-11:2011; EN 61643-11:2012; GB/T 18802.11-2020.

 