All Categories
AC SPD Class I

AC SPD Class I

230V T1+T2 AC SPD Surge Protective Device 25kA/100kA Surge Protector DIN Rail Surge Protection Devices

Inquiry
  • Overview
  • Inquiry
  • Related Products

 

 35.jpg

Product Description

 

Summary

BT BCM 25 RM(801031) power surge protector device is for installation at LPZ 0A-1 or higher, protecting low voltage equipment from surge damage. Applied in modular SPD Class I + Class II for  power supply systemsuch as power distribution-room,distribution-cabinet and other important power supply system.. Designed according to IEC 61643-11; EN 61643-11; GB/T 18802.11.

11.jpg

Hightlight Features

1. 10/350μs, 8/20μs sparkgap, L-N/L-PE/L-PEN/N-PE surge protection device.

2.  Lightning impulse current withstand max.25kA (10/350μs).

3.  Adopt hermetical GDT technology, high follow current extinguishing capacity.

4. Extremely low voltage protection level.

5.  Double thermals for parallel or series (V-shape) connection.

6. Multifunctional connection for conductors and pure copper busbar.

7.  Green light indicates power functional mode (L-PE/L-N/L-PEN module).

19.jpg

 

 

 

Technical data

Type

BT BCM 25 RM

Art.-No.

801031

According to IEC 61643-11 / EN 61643-11

Class I + Class II / Type 1 + Type 2

Nominal AC voltage [UN]

230V(50/60 Hz)

Rated voltage (max. continuous a.c. voltage) [ Uc ]

255V(50/60 Hz)

Lightning impulse current (10/350μs) [Iimp]

25kA

Nominal discharge current (8/20μs) [In]

50kA

Max. discharge current (8/20μs) [Imax]

100kA

Voltage protection level at In [Up]

≤ 1.8kV

Follow current extinguishing capability at Uc[If] 

32A fuse will not be triggered at 2kArms 255V

Response time [tA]    

≤ 25ns

TOV voltage[ UT ]

355V / 5sec

Max. back up fuse (L) [F]

200A gL/gG

Max. back up fuse (L-L’) [F]

125A gL/gG

Operating temperature range [Tu]

-40°C...+80°C

Cross-sectional area

10mm2~35mm2 solid / 50mm2 flexible

Mounting on

35mm DIN rail, EN 60715

Dimension

2 mods (36mm wide)

Certification

CE ; RoHS;ISO 9001:2015

Enclosure material

Purple thermoplastic, UL94-V0

Compliance

IEC 61643-11; EN 61643-11; GB/T 18802.11

Type of remote signalling contact

Switching contact

Switching capacity(UN/IN)

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;750V/0.5A

Cross-sectional area for remote signalling contact

Max. 1.5mm2 solid / flexible

 

Product Shows

15.jpg17.jpg16.jpg18.jpg9.jpg2.jpg

 

 Surge Protective Devices Combination

12.jpg9.jpg10.jpg12.jpg10.jpg9.jpg

 

1FAQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GET IN TOUCH