  3

13.jpg

Technical data

Type

BT P C TT1+1 385

BT P C TT1+1 385 RM

Art.-No. 

810111

According to IEC 61643-11/EN 61643-11

Class II (class 2/C) / Type 2

AC Nominal voltage[UN](50/60Hz)

230V

Rated voltage (max. continuous voltage) [Uc](50/60Hz)

385V(L-N)   255V(N-PE)

Nominal discharge current (8/20μs) [In]

20kA(L-N)   40kA(N-PE)

Max. discharge current (8/20μs) [Imax]

40kA(L-N)   65kA(N-PE)

Voltage protection level at In [Up]

 ≤1.8kV(L-N)   ≤1.5kV(N-PE)

Voltage protection level at 5kA [Up]

 ≤1.35kV(L-N)

Response time [tA]

≤ 25ns(L-N)  ≤ 100ns(N-PE)

TOV withstand 5sec[UT]

335V(L-N)

TOV 120 min(safe fail)[UT]

440V(L-N)

TOV withstand 200ms[UT]

1200V(N-PE)

Follow current extinguishing
capability at Uc [If]

100Arms(N-PE)

Max. back up fuse [F]

125A gL/gG

Short circuit withstand capability
at max. back up fuse

25kArms

Cross-sectional area 

1.5mm2 ~ 25mmsolid / 35mm2 flexible

Operating temperature range [Tu]

-40°C...+80°C

Mounting on 

35mm DIN rail, EN 60715 

Enclosure material

Purple thermoplastic, UL94-V0

Dimension 

2 mods (36mm wide) 

Compliance

 IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020

Certification

CE; RoHS

Number of remote terminals

0

1

Type of remote signaling contact

-

Switching contact

Switching capacity(UN/IN)

-

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A

Cross-sectional area for remote signaling contact

-

Max. 1.5mm2 (16AWG)solid/flexible

 14.jpg16.jpg

Hightlight Features

1.  Pluggable module, AC SPD 1P+N 385V 20-40kA T2, easy for installation and maintenance.

2.  Consist of High Energy MOV + High Energy GDT and thermal disconnection devices.

3. High discharge capacity, quick response.

4. Double thermal disconnector devices, providing more reliable protection.

5. Green window will change to red when fault occurs and also provide remote alarm control at the same time.

6. Suitable for use in single phase 220V-240V AC systems.

7. Suitable for TT/ TN installations. 

Summary

BT P C TT1+1 385 RM Designed for installation in LPZ 0B-1 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional.

Application:Pluggable SPD Class II for single-phase TT/TN (“1+1” circuit) power supply systems.

Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.