All Categories
AC SPD Class II

AC SPD Class II

SPD 3P+N 20kA-40kA T2 275V AC House Low Voltage Surge Protection Device for Three Phase

Inquiry
  • Overview
  • Inquiry
  • Related Products
Product Description
3

10.jpg

Technical Data

Type

BT PCM TT3+1 275 RM

BT PCM TT3+1 385 RM

According to IEC 61643-11 / EN 61643-11

Class II / Type 2

Class II / Type 2

Art.-No.

810813

810815

Nominal a.c. voltage[UN](50/60Hz)

230V/400V
230V/400V

Rated voltage (max. continuous voltage) [Uc] (L-N / N-PE)(50/60Hz)

275V/ 255V

385V/ 255V

Nominal discharge current (8/20μs) [In] (L-N / N-PE)

20kA / 40kA

20kA / 40kA

Max. discharge current (8/20μs) [Imax] (L-N / N-PE)

40kA / 65kA

40kA / 65kA

Voltage protection level at In [Up](L-N / N-PE)

≤ 1.3kV / ≤ 1.5kV

≤ 1.8kV / ≤ 1.5kV

Voltage protection level 5kA [Up](L-N)

≤ 1.0kV

≤ 1.35kV

TOV Withstand 5s[L-N ][UT]

336.6V

335V

TOV 120 min(safe fail)[UT][L-N ]

440V

TOV Withstand 200ms[N-PE ][UT]

1200V

Response time [tA](L-N / N-PE)

≤ 25ns / ≤ 100ns

Max. back up fuse [F]

125A gL/gG

Operating temperature range [Tu]

-40°C...+80°C

Cross-sectional area

1.5mm2(16AWG) ~25mm2(4AWG) solid / 35mm2(2AWG) flexible

Mounting on

35mm DIN rail, EN 60715

Enclosure material

Yellow & light grey (base) thermoplastic, UL94-V0

Number of Remote terminal

1 (or Optional)

Dimension

4 mods(72mm wide) 

Compliance

IEC 61643-11:2011 ; EN 61643-11:2012; GB/ 18802.11-2020

Certification

KEMA-KEUR, CE(LVD,EMC), CB, RoHS;REACH;ISO 9001:2015

Type of remote signalling contact

Switching contact

Switching capacity

AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;750V/0.5A

Cross-sectional area for remote signalling contact

Max.1.5mm2 (16AWG) solid / flexible

15.jpg

Hightlight Features

1. Pluggable module, easy for installation and maintenance.

2. High discharge capacity, quick response.

3. Double thermal disconnector devices, providing more reliable protection.

4. Green window will change when fault and also provide remote alarm control at the same time.

5. Surge protection device has passed KEMA-KEUR certification.

6. Suitable for use in three phase: 220V/380V(50/60 Hz), 240V/415V(50Hz), 230V/400V(50/60 Hz) AC systems.

7. Suitable for TT/ TN-S installations.

13.jpg

Summary

BT PCMTT3+1 275 RM Designed for installation in LPZ 0B-1 or higher zones, this surge protection device safeguards low-voltage equipment from power surgesand remote terminal is optional.

Application:

Pluggable SPD Class II for three-phaseTT/TN-S ("3+1" circuit) power supply systems.

Compliance Standards:

IEC 61643-11:2011

EN 61643-11:2012

GB/T 18802.11-2020.

12.jpg

Application environment

Temperature: -40°C ~ +80°C
Relative humidity: ≤ 95% (25°C)

Other

As China's first batch surge protection device manufacturer, we are committed to producing high-quality surge protection device while providing customized solutions for global industry leaders for over 30 years. Welcome OEM and ODM!

1FAQ

GET IN TOUCH